Powerfeed 84

Powerfeed 84 DEFAULT

Power Feed 84 – Single Boom Feeder, NO U/I - K3328-1

Advanced Process, Brands, Lincoln Electric, Wire Feeders

-

Top Features

  • New Auto-Settings simplify process setup
  • Eight User Memories – Per feed head for complete welding procedure recall
  • Improved isolation & environmental protection
  • Robust connection points allow for reliable operation in tough conditions
  • Modularity ensures the feeder can be configured to fit a variety of application needs

Processes

MIG, Pulsed MIG, MIG-STT®, Flux-Cored, Stick, TIG, Gouging

Gtin N/ASKU: K3328-1Categories: Advanced Process, Brands, Lincoln Electric, Wire Feeders

Features and Benefits

Digital Control Semiautomatic Wire Feeders

The Power Feed 84 family raises the bar for advanced process feeders by providing comprehensive process adjustability and control in a simple to use, rugged design.

 

Simple & Customizable Controls

  • New Auto-Settings simplify process setup
  • Eight User Memories – Per feed head for complete welding procedure recall
  • USB Port – Simplifies machine setup and expands user profiles
  • User Interface – Can be customized to display customer specific information
  • Contactor and gouge kit isolate the feedheads for additional safety

 

Rugged Design

  • Improved isolation & environmental protection
  • Robust connection points allow for reliable operation in tough conditions

 

Modular Platform

  • Modularity ensures the feeder can be configured to fit a variety of application needs

Specifications

SOLID WIRE SIZE RANGE.025 – 1/16 in (0.6 – 1.6 mm)
CORED WIRE SIZE RANGE.035 – .120 in (0.9 – 3.0 mm)
WIRE SPEED RANGE IPM (M/MIN)50-700 ipm (1.3-19 m/min)
DIMENSIONS (H X W X D)25.2 in x 15.5 in x 27.9 in (640 mm x 394 mm x 709 mm)
NET WEIGHT38.00 (17.24 kg)

What´s Included

  • Standard #2 – #4 gun adapter
  • 20 tooth pinion gear
  • Conduit inlet bushing (K3929-1)

Gtin N/ASKU: K3328-1Categories: Advanced Process, Brands, Lincoln Electric, Wire Feeders

Weight38.00 lbs
Dimensions27.9 × 15.5 × 25.2 in

Related products

    Sours: https://serviceweldingsupply.com/product/power-feed-84-single-boom-feeder-no-u-i/

    Caution – Lincoln Electric IM10178 POWER FEED 84 U.I. CONTROL BOX User Manual

    background image

    E-2

    TROUBLE SHOOTING

    Ifforanyreasonyoudonotunderstandthetestproceduresorareunabletoperformthetests/repairssafely,contactyour
    Local Lincoln Authorized Field Service Facility fortechnicaltroubleshootingassistancebeforeyouproceed.

    CAUTION

    POWER FEED 84, POWER FEED 84 DUAL

    ObserveallSafetyGuidelinesdetailedthroughoutthismanual

    PROBLEMS

    (SyMPTOMS)

    POSSIBLE

    CAUSE

    RECOMMENDED

    COURSE OF ACTION

    Fault Code

    Err 18 Configuration error

    Err 81 Motor overload, long term.

    Err 82 Motor overload, short term.

    The feeder does not power up - no voltage,
    no cold feed.

    The green LED on the wire drive or user
    interface is flashing quickly.

    The feeder is stuck in procedure B.

    Description

    1. The DIP switch setting for the user inter-

    face does not match the wire drives. The
    UI is set for “single” with a “dual” wire
    drive, or the UI is set for “dual” with a
    “single” wire drive.

    1. The wire drive motor has overheated.

    1. The wire drive motor current draw has

    exceeded limits, usually because the
    motor is in a locked rotor state.

    1. The work sense lead is disconnected or

    is a poor electrical connection. (Across
    the arc models)

    2. The power source is OFF.
    3. The circuit breaker for the wire feeder on

    power source have tripped. (control
    cable models)

    4. The control cable may be loose or dam-

    aged. (control cable models)

    1. Loss of ArcLink communication between

    the wire feeder and the power source.

    2. Loss of ArcLink communication between

    the wire drive and control box of boom
    systems

    3. Multiple feeders are connected to the

    power source.

    1. A dual procedure gun is being used with

    the dual procedure switch closed.

    Possible Adjustments

    1. Verify the user interface DIP is in the cor-

    rect position.

    1. Check that the electrode slides easily

    through the gun and cable.

    2. Remove tight bends from the gun and

    cable.

    3. Check that the spindle brake is not too

    tight.

    4. Verify a high quality electrode is being

    used.

    5. Wait for the error to reset and the motor

    to cool (approximately 1 minute).

    1. Check that motor can turn freely when

    idle arm is open.

    2. Verify that the gears are free of debris

    and dirt.

    1. Connect the work sense lead to the work

    in a location free of dirt, rust and paint.

    2. Turn ON the power source.
    3. Reset the circuit breakers.

    4. Tighten, repair or replace the control

    cable.

    1. Check cables for good connections.

    2. Check cables for good connections.

    3. Upgrade the software in the power

    source.

    1. Change the position of the dual proce-

    dure switch.

    ArcLink System Error Codes

    Sours: https://www.manualsdir.com/manuals/356669/lincoln-electric-im10178-power-feed-84-ui-control-box-im10178-power-feed-84-dual-control-box-im10178-power-feed-84-control-box.html?page=79
    1. Workhorse recall
    2. Microsoft word psu
    3. Herend collections
    4. Ariel doll dress
    5. Matching key padlocks

    Power Feed 84 – U/I, HVY. DTY REEL, USB - K3328-13

    Advanced Process, Brands, Lincoln Electric, Wire Feeders

    -

    Top Features

    • New Auto-Settings simplify process setup
    • Eight User Memories – Per feed head for complete welding procedure recall
    • Improved isolation & environmental protection
    • Robust connection points allow for reliable operation in tough conditions
    • Modularity ensures the feeder can be configured to fit a variety of application needs

    Processes

    MIG, Pulsed MIG, MIG-STT®, Flux-Cored, Stick, TIG, Gouging

    Gtin 00015082560823SKU: K3328-13Categories: Advanced Process, Brands, Lincoln Electric, Wire Feeders

    Features and Benefits

    Digital Control Semiautomatic Wire Feeders

    The Power Feed 84 family raises the bar for advanced process feeders by providing comprehensive process adjustability and control in a simple to use, rugged design.

     

    Simple & Customizable Controls

    • New Auto-Settings simplify process setup
    • Eight User Memories – Per feed head for complete welding procedure recall
    • USB Port – Simplifies machine setup and expands user profiles
    • User Interface – Can be customized to display customer specific information
    • Contactor and gouge kit isolate the feedheads for additional safety

     

    Rugged Design

    • Improved isolation & environmental protection
    • Robust connection points allow for reliable operation in tough conditions

     

    Modular Platform

    • Modularity ensures the feeder can be configured to fit a variety of application needs

    Specifications

    SOLID WIRE SIZE RANGE.025 – 1/16 in (0.6 – 1.6 mm)
    CORED WIRE SIZE RANGE.035 – .120 in (0.9 – 3.0 mm)
    WIRE SPEED RANGE IPM (M/MIN)50-700 ipm (1.3-19 m/min)
    DIMENSIONS (H X W X D)25.2 in x 15.5 in x 27.9 in (640 mm x 394 mm x 709 mm)
    NET WEIGHT62.00 (28.12 kg)

    What´s Included

    • User Interface
    • Standard #2 – #4 gun adapter
    • 20 tooth pinion gear
    • 8 ft. (2.4 m) control cable (K1543-8)
    • USB
    • Heavy duty reel stand

    Gtin 00015082560823SKU: K3328-13Categories: Advanced Process, Brands, Lincoln Electric, Wire Feeders

    Weight62.00 lbs
    Dimensions27.9 × 15.5 × 25.2 in

    Related products

      Sours: https://serviceweldingsupply.com/product/power-feed-84-u-i-hvy-dty-reel-usb/
      Precision Pulse™

      POWER FEED® 84 DUAL BENCH WIRE FEEDER - U/I, HVY. DTY REEL, CNTCRS., USB - K3330-5

      Features

      Digital Control Semiautomatic Wire Feeders

      The Power Feed 84 family raises the bar for advanced process feeders by providing comprehensive process adjustability and control in a simple to use, rugged design.

       

      Simple & Customizable Controls

      • New Auto-Settings simplify process setup
      • Eight User Memories – Per feed head for complete welding procedure recall
      • USB Port – Simplifies machine setup and expands user profiles
      • User Interface – Can be customized to display customer specific information
      • Contactor and gouge kit isolate the feedheads for additional safety

       

      Rugged Design

      • Improved isolation & environmental protection 
      • Robust connection points allow for reliable operation in tough conditions

       

      Modular Platform

      • Modularity ensures the feeder can be configured to fit a variety of application needs
      Sours: https://www.americanweldingsupply.com/power-feedr-84-dual-bench-wire-feeder-u-i-hvy-dty-reel-cntcrs-usb-k3330-5.html

      84 powerfeed

      84 SERIES
      4Pages

      SEMIAUTOMATIC WIRE FEEDERS Power Feed 84 and Power Feed 84 Dual ® Processes MIG, Pulsed MIG, MIG-STT®, Flux-Cored, Stick, TIG, Gouging Product Number K3328-XX – Single Feeder Models K3330-XX – Dual Feeder Models K3336-XX – Control Boxes Input Power 40 VDC Output Capacity Current/Duty Cycle 600A/60% Wire Size Range .025-.120 in. (0.6 - 3.0 mm)(3) Wire Feed Speed 50-1200 (1.3-30.4)(1)(2) Weight/Dimensions (H x W x D) 25.2 x 15.5 x 27.9 (640 x 394 x 709) single wire drive * See back for details Digital Control Semiautomatic Wire Feeders The Power Feed 84 family raises the bar for advanced process feeders by providing comprehensive process adjustability and control in a simple to use, rugged design. FEATURES Simple & Customizable Controls – - New Auto-Settings simplify process setup - Eight User Memories – Per feed head for complete welding procedure recall - User Interface – Can be customized to display customer specific information - Contactor and gouge kit isolate the feedheads for additional safety Rugged Design – - Improved isolation & environmental protection - Robust connection points allow for reliable operation in tough conditions 20 tooth pinion gear installed in the wire drive as equipped from the factory. (2) To achieve a wire feed speed of 1200, the feeder is configured with a 30 tooth pinion gear (3) Variation in the wire size range is dependent on the configuration of the 20 or 30 tooth pinion gear (1) RECOMMENDED POWER SOURCES Power Wave® 455M Power Wave 455M/STT® Power Wave S350 Power Wave S500 Power Wave S700 WHAT’S INCLUDED Bench Models Include: All bench models include a standard #2 - #4 gun adapter 20 tooth pinion gear All wire feeders with a wire reel stand include a 8 ft. (2.4 m) control cable (K1543-8) All wire feeders without a wire reel stand include a conduit inlet bushing (K3929-1) THE LINCOLN ELECTRIC COMPANY Publication E8.268 | Issue D­ te 04/14 a © Lincoln Global, Inc. All Rights Reserved. 22801 St. Clair Avenue • Cleveland, OH • 44117-1199 • U.S.A. PH: +1.216-481-8100 • www.lincolnelectric.com Modular Platform – Modularity ensures the feeder can be configured to fit a variety of application needs Power Feed 84 Dual and Power Feed 84 - USB Port – Simplifies machine setup and expands user profiles Two Year Extended Warranty Available in the U.S.A. and Canada

      Open the catalog to page 1
      Sours: https://pdf.directindustry.com/pdf/lincoln-electric/84-series/7970-561620.html
      ALSGS power feed for ZX7045 \u0026 RF45 clones - small teardown

      Operator's Manual

      POWER FEED 84

      POWER FEED 84 U.I. CONTROL BOX

      POWER FEED 84 SINGLE

      Power Feed 84 Dual

      Register your machine:

      www.lincolnelectric.com/registration

      Authorized Service and Distributor Locator:

      www.lincolnelectric.com/locator

      Save for future reference

      Date Purchased

      Code: (ex: 10859)

      Serial: (ex: U1060512345)

      IM10178-E

      | Issue D ate July-16

      © Lincoln Global, Inc. All Rights Reserved.

      For use with machines having Code Numbers:

      Power Feed 84: 11986, 11987, 11988,

      11989, 11990, 11991, 11993, 11994,

      11996, 11997, 11998, 12274, 12275,

      12276, 12277, 12278, 12279, 12280,

      12281, 12282, 12283, 12284, 12517,

      12520, 12521, 12522, 12523, 12524,

      12525, 12526, 12527, 12528, 12529,

      12530, 12578

      Power Feed 84 Dual: 12108, 12109,

      12110, 12111, 12112, 12113, 12115,

      12116, 12285, 12286, 12287, 12288,

      12289, 12290, 12291, 12292, 12518,

      12578, 12531, 12532, 12533, 12534,

      12535, 12536, 12537, 12538, 12579

      Power Feed 84 U.I. Control Box:

      12177, 12178, 12179

      Sours: https://www.manualslib.com/manual/1430933/Lincoln-Electric-Power-Feed-84-Single.html

      You will also be interested:

      A couple of seconds passed, and it dawned on her that this was beyond the scope of companionship. She got up to look into her eyes and asked: - Gee, you say that Andrey is boring. Okay, what else did you see. I didn't see anything, she whispered. - That is why I ask you.



      481 482 483 484 485